24 V DC power architectures selected around load current, inrush, buffering and diagnostics.

Honghao reviews steady-state load, simultaneous inrush, redundancy, selectivity and outage-bridging requirements before selecting the supply and add-on modules. Exact input range, output current and approvals are confirmed by article number.

Request price & lead time Final specifications are confirmed by article number.
SITOP industrial power supply and DC UPS products

Common SITOP searches

Decisions that change the BOM.

Review these points before choosing a model name or requesting a replacement.

01How do I size a 24 V DC power supply for a PLC panel?
24V PLC power supply sizing

Create a load schedule for continuous current and simultaneous inrush, include branch behavior and future spare capacity, then check input network, ambient derating, redundancy, selectivity and diagnostics. Nameplate current totals alone can miss startup peaks.

View PSU6200 selection data
02When is a SITOP DC UPS needed?
SITOP DC UPS selection

Use a DC UPS when short outages must not stop controls immediately, or when the PLC, HMI or industrial computer needs time for controlled shutdown. Define protected loads, bridge time, battery or capacitor strategy, diagnostics and maintenance responsibility.

Review DC UPS parameters
03What is electronic selectivity in a 24 V system?
24V DC selectivity PLC panel

Selective protection separates overloaded or shorted 24 V branches so a single fault is less likely to collapse the whole control supply. Branch current, cable, inrush, trip behavior and diagnostic integration must be coordinated with the power supply.

See the control-power review

Product range

SITOP series overview

Compare the SITOP options below before choosing a series. The final CPU, power module, control unit or accessory is selected from approved project data and the complete article number.

01

Basic 24 V power supply

SITOP PSU4200

Standard machine and panel loads
  • Compact installation
  • 24 V DC supply
  • Basic diagnostics
View parameters & selection
02

High-performance standard supply

SITOP PSU6200

Machines requiring power reserves and diagnostics
  • Up to 40 A variants
  • Power reserve
  • Diagnostic contact
View parameters & selection
03

24 V ride-through

SITOP DC UPS

Controlled shutdown and outage bridging
  • UPS1600 platform
  • Battery or capacitor options
  • System diagnostics
View parameters & selection

Selection checklist

Information we review

Providing the listed SITOP application data early reduces configuration changes and keeps the quotation aligned with the actual machine or process.

Load current
Continuous load, simultaneous starting current and future spare capacity
Input supply
Single-phase or three-phase voltage, frequency and network quality
Availability
Redundancy, selective shutdown and required ride-through duration
Diagnostics
Dry contact, Ethernet/PROFINET integration and maintenance alarms

Honghao support

Supply and engineering scope

  • 24 V load and inrush review
  • Power supply, UPS and selectivity BOM
  • Cabinet power-distribution design
  • Battery and maintenance planning support

Typical applications

Where this family fits

PLC panelsMachine controlsProcess skidsNetwork cabinetsCritical instrumentation

Selection questions

Before you specify SITOP.

These SITOP answers cover the decisions most likely to change the article number, accessories, replacement plan or control-panel scope.

01

SITOP selection questions

Questions buyers ask before choosing industrial power & dc ups.

How do I size a 24 V DC power supply for a PLC panel?
24V PLC power supply sizing

Create a load schedule for continuous current and simultaneous inrush, include branch behavior and future spare capacity, then check input network, ambient derating, redundancy, selectivity and diagnostics. Nameplate current totals alone can miss startup peaks.

View PSU6200 selection data
When is a SITOP DC UPS needed?
SITOP DC UPS selection

Use a DC UPS when short outages must not stop controls immediately, or when the PLC, HMI or industrial computer needs time for controlled shutdown. Define protected loads, bridge time, battery or capacitor strategy, diagnostics and maintenance responsibility.

Review DC UPS parameters
What is electronic selectivity in a 24 V system?
24V DC selectivity PLC panel

Selective protection separates overloaded or shorted 24 V branches so a single fault is less likely to collapse the whole control supply. Branch current, cable, inrush, trip behavior and diagnostic integration must be coordinated with the power supply.

See the control-power review
02

Quotation and compatibility

The information needed for a technically usable offer.

What should I send for a SITOP quotation?
SITOP quotation

Send the full article number for replacements. For a new application, provide load current, input supply, availability, diagnostics, quantity, destination and required delivery date. Honghao will identify assumptions before confirming the BOM.

Send product or application data
How does Honghao verify SITOP compatibility?
SITOP compatibility check

The review checks the complete article number, product generation, required accessories, electrical and communication interfaces, lifecycle status and the surrounding system. Final ratings remain tied to current manufacturer documentation and the approved BOM.

See the BOM verification method
Can SITOP products be supplied inside a complete control panel?
SITOP control panel

Yes, when the contracted scope includes panel engineering. The design basis should define power, protection, environment, interfaces, drawings, programming responsibility, FAT and export documentation before assembly.

Explore engineered solutions

Ready for review

Send the article number, BOM or application data.

Start your RFQ